Page 1825
no more than 44 inches from the sill, if the step does not create a tripping hazard, block wheelchair access in the bedroom, or block a heating element; or
(ii) 48 inches above the floor if the window is located in the basement, and the home does not already meet the standard in (i) of this subparagraph; the home must meet the standard in (i) of this subparagraph if the bedroom is remodeled or a new bedroom is constructed;
(B) the net clear openable area must be a minimum of five square feet for windows; for purposes of this subparagraph, the net clear openable height may not be less than 22 inches and the width may not be less than 20 inches;
(C) for floor windows other than grade floor, the net clear openable area must be a minimum of 5. 7 square feet; the net clear openable height may not be less than 24 inches and the net clear openable width may not be less than 20 inches; a window screen may not be used if it permanently prevents exit or if it cannot be easily removed for exit;
(4) the foster home and premises are free of any accumulation of combustible waste material and other fire hazards;
(5) at least one AC primary-powered smoke detection device with battery backup, or at least one monitored battery-powered smoke detection device, is located in each bedroom; in addition, if the foster home is multi-level, at least one smoke detection device must be installed on each level; each device required under this paragraph must be less than 10 years old, or newer if necessary to comply with the manufacturer’s recommended replacement date; in this paragraph, “AC” means alternating current;
(6) at least one fully charged 2A:10BC multipurpose dry chemical fire extinguisher is strategically located on each level of the facility, and is maintained, serviced, and replaced according to manufacturer’s instructions; and
(7) any flammable or combustible liquid is stored in a container with a tight-fitting lid that is specifically designed for holding flammable or combustible liquids; the foster home shall ensure that these liquids are kept out of the reach of children. (Eff. 7/1/2022, Register 242) Statutory Authority: Authority: AS 44.30.020 AS 47.32.020 AS 47.32.110
AS 47.14.120 AS 47.32.030
AS 47.32.010 AS 47.32.032